WHITE CEMENT BASED POLYMER MODIFIED MORTAR
Measurements
- Length and breadth shall be measured correct to a cm. The area shall be calculated in square metre correct to two places of decimal.
- Pre- measurements of the patches to be plastered shall be recorded after the old plaster has been cut and surface prepared.
WHITE WASHING WITH LIME, WHITE WASHING WITH WHITING, COLOUR WASHING, DRY DISTEMPERING, OIL EMULSION (OIL BOUND) WASHABLE DISTEMPERING, 1st QUALITY ACRYLIC DISTEMPER, EXTERIOR PAINTING ON WALL
Measurements
- Length and breadth shall be measured correct to a cm. and area shall be calculated in sqm correct to two places of decimals.
- Measurements for Jambs, Soffits and Fills etc. for openings shall be as described in Cement Plaster.
- Corrugated surfaces shall be measured flat as fixed and the area so measured shall be increased by the following percentages to allow for the girthed area.
- Corrugated non-asbestos cement sheet 20%
- Semi corrugated non-asbestos cement sheet 10%
- Cornices and other such wall or ceiling features, shall be measured along the girth and included in the measurements.
- The number of coats of each treatment shall be stated. The item shall include removing nails, making good holes, cracks, patches etc. not exceeding 50 sq. cm. each with material similar in composition to the surface to be prepared.
- Work on old treated surfaces shall be measured separately and so described.
PAINTING
Measurements
- The length and breadth shall be measured correct to a cm. The area shall be calculated in sqm (correct to two places of decimal), except otherwise stated.
- Small articles not exceeding 10 sq. decimetre (0.1 sqm) of painted surfaces where not in conjunction with similar painted work shall be enumerated.
- Painting upto 10 cm in width or in girth and not in conjunction with similar painted work shall be given in running metres and shall include cutting to line where so required.
- Note : Components of trusses, compound girders, stanchions, lattices and similar work shall, however, be given in sq. metres irrespective of the size or girth of members. Priming coat of painting shall be included in the work of fabrication.
- In measuring painting, varnishing, oiling etc. of joinery and steel work etc. The coefficients as indicated in following tables shall be used to obtain the area payable. The coefficients shall be applied to the areas measured flat and not girthed.
Equivalent Plain Areas of Uneven Surface
S.No | Description of work | How measured | Multiplying coefficient |
1 | 2 | 3 | 4 |
I. Wood work doors, windows Etc | |||
1 | Panelled or framed and braced doors, windows etc. | Measured flat (not girthed including) | 1.30 (for each side) |
2 | Ledged and battened or ledged, battened and braced doors, windows etc. | Chowkhat or frame, Edges, chocks, cleats, etc. shall be deemed to be included in the item. | -do- |
3 | Flush doors etc. | -do- | 1.20 (for each side) |
4 | Part panelled and part glazed or gauzed doors, window etc. (Excluding painting of wire gauze portion) | -do- | 1.00 (for each side) |
5 | Fully glazed or gauzed doors, windows etc. (Excluding painting of wire gauze portion) | -do- | 0.80 (for each side) |
6 | Fully venetioned or louvered doors, windows etc. | -do- | 1.80 (for each side) |
7 | Trellis (or Jaffri) work one way or two way | Measured flat overall, no deduction shall be made for open spaces, supporting members shall not be measured separately | 2 (for painting all over) |
8 | Carved or enriched work | Measured flat | |
9 | Weather boarding | Measured flat (not girthed supporting frame work shall not be measured separately | 1.20 (for each side) |
10 | Wood shingle roofing | Measured flat (not girthed) | 1.10 (for each side) |
11 | Boarding with cover fillets and match boarding | Measured flat (not girthed) | 1.05 (for each side) |
12 | Tile and slate battening | Measured flat overall no deductions shall be made for open spaces | 0.80 (for painting all over) |
II. Steel work doors, windows Etc. | |||
13 | Plain sheeted steel doors or windows | Measured flat (not girthed) including frame edges etc. | 1.10 (for each side) |
14 | Fully glazed or gauzed steel doors and windows (excluding painting of wire gauze portion) | -do- | 0.50 (for each side) |
15 | Partly panelled and partly glazed or gauzed doors and windows (excluding painting of wire gauze portion) | -do- | 0.80 (for each side) |
16 | Corrugated sheeted steel doors or windows | -do- | 1.25 (for each side) |
17 | Collapsible gates | Measured flat | 1.50 (for painting all over) |
18 | Rolling shutters of interlocked laths | Measured flat (size of opening) all over; jamb guides, bottom rails and locking arrangement etc. shall be included in the item (top cover shall be measured separately) | 1.10 (for each side) |
III. General | |||
19 | Expanded metal, hard drawn steel wire fabric of approved quality, grill works and gratings in guard bars, balustrades, railing partitions and MS Bars in windows frames. | Measured flat overall; no deduction shall be made for open spaces; supporting members shall not be measured separately | 1 (for Paint all over) |
20 | Open palisade fencing and gates including standards, braces, rails stays etc. in timber or steel | -do- (See note No.12) | 1 (for Paint all over) |
21 | Corrugated iron sheeting in roofs, side cladding etc. | do- Measured flat (not girthed) | 1.14 (for each side) |
22 | AC corrugated sheeting in roofs, side cladding etc. | -do- | 1.20 (for each side) |
23 | AC semi corrugated sheeting in roofs, side cladding etc. or Nainital pattern using plain sheets | -do- | 1.10 (for each side) |
24 | Wire gauze shutters including painting of wire gauze | -do- | 1.00 (for each side) |
25 | Hait Cut Bamboo fencing | -do- | 1.38 (AV) (for each side) |
Explanatory Notes for Table
- Measurements for doors windows etc., shall be taken flat (and not girthed) over all including chowkhuts or frames, where provided. Where Chowkhuts or frames are not provided, the shutter measurements shall be taken.
- Where doors, windows etc., are of composite types other than those included in Table 1 the different portion shall be measured separately with their appropriate coefficients, the centre line of the common rail being taken as the dividing line between the two portions.
- The coefficients for door and windows shall apply irrespective of the size of frames and shutter members.
- In case steel frames are used the area of doors, windows shutters shall be measured flat excluding frames.
- When the two faces of a door, window etc. are to be treated with different specified finishes, measurable under separate items, the edges of frames and shutters shall be treated with the one or the other type of finish as ordered by the Engineer-in-Charge and measurement of this will be deemed to be included in the measurement of the face treated with that finish.
- In the case where shutters are fixed on both faces of the frames, the measurement for the door frame and shutter on one face shall be taken in the manner already described, while the additional shutter on the other face will be measured for the shutter only excluding the frame.
- Where shutters are provided with clearance at top or/and bottom each exceeding 15 cm height, such openings shall be deducted from the overall measurements and relevant coefficient shall be applied to obtain the area payable.
- Collapsible gates shall be measured for width from outside to outside of gate in its expanded position and for height from bottom to top of channel verticals. No separate measurements shall be taken for the top and bottom guide rails rollers, fittings etc.
- Coefficients for sliding doors shall be the same as for normal types of doors in the table. Measurements shall be taken outside to outside of shutters, and no separate measurements shall be taken for the painting guide rails, rollers, fittings etc.
- Measurements of painting as above shall be deemed to include painting all iron fittings in the same or different shade for which no extra will be paid.
- The measurements of guard bars, expanded metal, hard drawn steel wire fabric of approved quality, grill work and gratings, when fixed in frame work, painting of which is once measured else where shall be taken exclusive of the frames. In other cases the measurements shall be taken inclusive of the frames.
- For painting open palisade fencing and gates etc., the height shall be measured from the bottom of the lowest rail, if the palisades do not go below it, (or from the lower end of the palisades, if they project below the lowest rail), upto the top of rails or palisades whichever are higher, but not up to the top of standards when the latter are higher than the top rails or the palisades.
5. Width of moulded work of all other kinds, as in hand rails, cornices, architraves shall be measured by girth.
6. For trusses, compound girders, stanchions, lattice girders, and similar work, actual areas will be measured in sq. metre and no extra shall be paid for painting on bolt heads, nuts, washers etc. even when they are picked out in a different tint to the adjacent work.
7. Painting of rain water, soil, waste, vent and water pipes etc. shall be measured in running metres of the particular diameter of the pipe concerned. Painting of specials such as bends, heads, branches, junctions, shoes, etc. shall be included in the length and no separate measurements shall be taken for these or for painting brackets, clamps etc.
8. Measurements of wall surfaces and wood and other work not referred to already shall be recorded as per actual.
9. Flag staffs, steel chimneys, aerial masts, spires and other such objects requiring special scaffolding shall be measured separately.
EPOXY PAINT, PAINTING WITH WOOD PRESERVATIVE, FIRE RETARDANT PAINT, SPRAY PAINTING WITH FLAT WALL PAINT ON NEW SURFACE, MELAMINE POLISH, FRENCH SPIRIT POLISHING
Measurement
- The length and breadth shall be measured correct to a cm. The area shall be calculated in sqm (correct to two places of decimal), except otherwise stated.
- Small articles not exceeding 10 sq. decimetre (0.1 sqm) of painted surfaces where not in conjunction with similar painted work shall be enumerated.
- Painting upto 10 cm in width or in girth and not in conjunction with similar painted work shall be given in running metres and shall include cutting to line where so required.
- Note : Components of trusses, compound girders, stanchions, lattices and similar work shall, however, be given in sq. metres irrespective of the size or girth of members. Priming coat of painting shall be included in the work of fabrication.
- In measuring painting, varnishing, oiling etc. of joinery and steel work etc. The coefficients as indicated in following tables shall be used to obtain the area payable. The coefficients shall be applied to the areas measured flat and not girthed.
- Width of moulded work of all other kinds, as in hand rails, cornices, architraves shall be measured by girth.
- For trusses, compound girders, stanchions, lattice girders, and similar work, actual areas will be measured in sq. metre and no extra shall be paid for painting on bolt heads, nuts, washers etc. even when they are picked out in a different tint to the adjacent work.
- Painting of rain water, soil, waste, vent and water pipes etc. shall be measured in running metres of the particular diameter of the pipe concerned. Painting of specials such as bends, heads, branches, junctions, shoes, etc. shall be included in the length and no separate measurements shall be taken for these or for painting brackets, clamps etc.
- Measurements of wall surfaces and wood and other work not referred to already shall be recorded as per actual.
- Flag staffs, steel chimneys, aerial masts, spires and other such objects requiring special scaffolding shall be measured separately.
PAINTING CAST IRON RAIN WATER, SOIL, WASTE AND VENT PIPES AND FITTINGS
Measurements
- Measurements will be taken over the finished line of pipe including specials etc. in running metres, correct to a cm.
- Pipes of different diameters of bore shall be measured and paid for separately. Specials and fittings such as holder bat clamps, plugs etc. will not be measured separately.
LETTERING WITH PAINT
Measurements
- Measurements shall be taken in terms of letter cm (the measurement relates to the vertical height of the lettering). The letter heights shall be measured correct to a cm. Dots, dashes, punctuations and other similar marks or lines shall not be measured for payment.
- In Devanagari Script Dots & Matras occurring with the letters shall not be measured. Half letter shall be measured as full letter. The height of letters shall be measured excluding the Matras projecting above the heading and matras below the letters.
REMOVING OLD PAINT
Measurements
- The length and breadth shall be measured correct to a cm. The area shall be calculated in sqm (correct to two places of decimal), except otherwise stated.
- Small articles not exceeding 10 sq. decimetre (0.1 sqm) of painted surfaces where not in conjunction with similar painted work shall be enumerated.
- Painting upto 10 cm in width or in girth and not in conjunction with similar painted work shall be given in running metres and shall include cutting to line where so required.
- Note : Components of trusses, compound girders, stanchions, lattices and similar work shall, however, be given in sq. metres irrespective of the size or girth of members. Priming coat of painting shall be included in the work of fabrication.
- In measuring painting, varnishing, oiling etc. of joinery and steel work etc. The coefficients as indicated in following tables shall be used to obtain the area payable. The coefficients shall be applied to the areas measured flat and not girthed.
- Width of moulded work of all other kinds, as in hand rails, cornices, architraves shall be measured by girth.
- For trusses, compound girders, stanchions, lattice girders, and similar work, actual areas will be measured in sq. metre and no extra shall be paid for painting on bolt heads, nuts, washers etc. even when they are picked out in a different tint to the adjacent work.
- Painting of rain water, soil, waste, vent and water pipes etc. shall be measured in running metres of the particular diameter of the pipe concerned. Painting of specials such as bends, heads, branches, junctions, shoes, etc. shall be included in the length and no separate measurements shall be taken for these or for painting brackets, clamps etc.
- Measurements of wall surfaces and wood and other work not referred to already shall be recorded as per actual.
- Flag staffs, steel chimneys, aerial masts, spires and other such objects requiring special scaffolding shall be measured separately.
PAINTING CAST IRON RAIN WATER, SOIL, WASTE AND VENT PIPES AND FITTINGS
Measurements
- Measurements will be taken over the finished line of pipe including specials etc. in running metres, correct to a cm.
- Pipes of different diameters of bore shall be measured and paid for separately.
- Specials and fittings such as holder bat clamps, plugs etc. will not be measured separately.